Closing the Gaps - RV Enthusiast Magazine

Closing the Gaps

by | Nov 9, 2022 | Pro Tip, RVEXPERT

Photos by author
Sealing the vent holes in the access panels is part of the process when retrofitting an absorption refrigerator for a residential or 12-volt DC compressor model.
The trend to opting for compressor-type refrigerators as standard equipment in RVs these days is moving along at a rapid rate. The popularity of 12-volt DC refrigerators is growing every year, offering a practical alternative to residential models, which require 120-volt AC power. As the market expands, so does the viability of replacing an absorption refrigerator with a direct-fit model that can be accomplished by handy do-it-yourselfers.

I made the switch to a 12-volt DC Everchill model a year ago and enjoy the versatility of running on battery power — and the increase in food-storage capacity. Other than routing 12-volt DC power to the refrigerator compartment and plugging the LP-gas line, the hardest part of such a project was the heavy lifting. The other consideration was closing off the holes in the exterior access panels, which will prevent an unwanted breeze into the living quarters from the wind and provide an added level of insulation.

Top and bottom access panels were necessary to allow for adequate cooling of the absorption refrigerator, which was mounted in the galley slideout room. These panels are not used by manufacturers when installing a compressor-type refrigerator, so for this project most of the holes were plugged with an aluminum insulation material. For this installation, the bottom row of vent holes on each panel was left open to allow for some airflow without creating a windstorm inside the fifth wheel. I figured this would be beneficial when parked in places with hot climates, but I have no science to back this up (other than it makes sense). The box temperature in this refrigerator has not fluctuated more than 2 degrees F, unless the door was left open for loading.

RV technician removes a vent covering installed in the sidewall behind the absorption refrigerator
Two exterior access panels were factory installed in the sidewall behind the absorption refrigerator to allow for proper airflow. Once the original refrigerator was swapped for a 12-volt DC compressor model, these panels were unneeded and insulated with Kozy Wrap to control the wind blowing into the interior.
the Kozy Wrap is laid out on a table and measured
the Kozy Wrap is laid out on a table and measured
After measuring the inside of one access panel (both are the same size) the Kozy Wrap was laid out on a table and measured. A steel straight edge ruler was necessary to mark the cut lines.
the Kozy Wrap was taped at one end with a good-quality aluminum tape
the RV tech continues to line the vent covering with Kozy Wrap
The Kozy Wrap was taped at one end to make it possible to closely fit the material around the vents in the panel. This aluminum-based insulation is lightweight and easy to “bend” into place. Make sure you use a good-quality aluminum tape like the product from 3M.
a small piece of aluminum tape is attached to prevent unraveling
After the Kozy Wrap was molded around the ends of the extrusions created by the vents, a small piece of aluminum tape was attached to prevent unraveling.
The Kozy Wrap was taped at one end to make it possible to closely fit the material around the vents in the panel. This aluminum-based insulation is lightweight and easy to “bend” into place. Make sure you use a good-quality aluminum tape like the product from 3M.
After the Kozy Wrap was molded around the ends of the extrusions created by the vents, a small piece of aluminum tape was attached to prevent unraveling.
insulation is cut around the latches that lock the access panels in place
The insulation was cut around the latches that lock the access panels in place. Make sure you don’t apply more than one layer of aluminum tape on the edges of the access panels otherwise they might not seat in the frame.
the completed vent covering, lined with Kozy Wrap with the bottom row of vent holes on each panel left open to allow for some airflow into the refrigerator compartment
The bottom row of vent holes on each panel was left open to allow for some airflow into the refrigerator compartment. There are no specific instructions for this step; I was just flying by the seat of my pants.

The stuff used is called Kozy Wrap, which is a very thin aluminum product with an extremely high insulative value. It’s employed by RV manufacturers (and the building industry) and is very lightweight.

Kozy Wrap is produced by Radiant Technology composites in Texas and, normally, is distributed via commercial channels. However, after we spoke with a company representative, the company adjusted its minimum-purchase requirements — and will now help individuals procure small amounts for DIY projects. Just log on to radiant-technology.com for more information.

Installing the product is relatively easy, requiring measuring, cutting and taping — Kozy Wrap is the most lightweight and flexible insulation I have ever worked with. Simply cut the material to size and attach it to the inside of the access panel using aluminum tape.

Over the years, I’ve also used this material to insulate the belly pan, the area behind the oven when remodeling the galley, the skylight in the bathroom and the windows (temporarily) when camping in cold weather. It’s awesome material, but not inexpensive.

Get Updates
Subscribe today and never miss an issue!
Get all the latest tips and news to keep you moving on that open road!
RV Enthusiast January/March 2024 Issue
Current Issue
January/March 2024
Spring is back in bloom and with it we are proud to present our latest issue of RV Enthusiast! The January/March issue covers furnace failures and how to fix them, the best batteries for boondocking, quick and easy weekend projects, PLUS so much more!

Already a Subscriber? Click here for Access to the Full Issues.

Share This